Troubleshooting
The most common Connect messages and what to do.
- Applies to
- Browser, Windows
- Included in
- Professional, Dedicated
- Version
- MediSync Connect 0.1.4
Find the message you see below. In the messages, three dots (…) stand for a name, number or time, for example the name of your PVS. Messages that only one PVS shows are listed under Messages for each PVS.
| What you see | What you do |
|---|---|
| Connect says that your PVS does not answer. | Start the PVS. More |
| A tick is missing in the setup. | Do the step in the PVS. More |
| Connect cannot reach a folder. | Create the folder, grant write access. More |
| The Dashboard says Connect is offline. | Switch on the practice PC. More |
| Connect says No connection to MediSync. | Check the internet. More |
| Connect cannot find the patient in the PVS. | Add the patient, send again. More |
| Connect does not answer on this computer. | Restart the computer. More |
The PVS does not answer
Message on screen
… does not answer
Message on screen
Since …. Connect keeps trying.
Message on screen
… does not answer. Is … running?
Start your PVS or the computer it runs on. Connect then sends the waiting entries automatically. If the PVS runs on a server, check the server name in Connect under Systems. If your PVS exchanges files with Connect through folders, a folder is usually missing. See Folder not reachable. If the problem lasts more than an hour, contact your PVS support first, then MediSync support.
A preparation step is missing
You do some setup steps in the PVS itself. Connect checks what it can. Under What Connect checked, it shows what is still missing. Do the step in the PVS, then click Check. The article for your PVS lists its steps. For messages that only one PVS shows, see Messages for each PVS.
Message on screen
Connect may not write in the ….
Your IT gives Connect write access to the folder. See Folder not reachable.
Folder not reachable
Some PVS exchange files with Connect through folders. If Connect cannot reach a folder, you see one of these messages.
Message on screen
Connect cannot reach the … exchange folder. Does the folder exist, and may Connect write there?
Message on screen
Connect cannot reach this folder. Does it exist, and may Connect write there?
- Create the folder. It must be the same folder that the PVS uses.
- Use a folder on this computer, for example
C:\GDT\Medisync\In, or a network path such as\\server\GDT. Do not use a mapped drive letter such asZ:. - Your IT gives the service account
NT SERVICE\MediSyncConnectHubwrite access to the folder. Then click Try again.
Connect is offline
Message on screen
Connect is offline
Message on screen
The practice PC is off or offline. Your note stays saved here.
Switch on the practice PC that runs Connect and check its internet connection. The note then goes into the PVS automatically. It waits up to 24 hours, then expires.
No connection to MediSync
Message on screen
No connection to MediSync
Message on screen
Your internet or MediSync is not reachable now. … works.
Open a web page on this computer. If that fails, the internet is down. If the web page opens, ask your IT to check the firewall and proxy. Connect for IT lists the addresses Connect needs.
Please sign in
Message on screen
Please sign in
Click Sign in.
Patient not found
Message on screen
Patient not found in …
Add the patient in the PVS or correct the name. Then click Send again. If you already entered the note by hand, click I entered it.
Code is wrong
This message can appear when you set up Connect with a code from MediSync support.
Message on screen
This code is wrong or no longer valid. Ask MediSync support for a new code.
A code is valid for 10 minutes. After 5 wrong tries, it is no longer valid. Paste the code with Ctrl+V, without spaces. If the code is no longer valid, ask MediSync support for a new one.
Already sent
Message on screen
Already sent
Message on screen
Sent to … on … at ….
The note is already in the PVS. To send it a second time, click Send again. The PVS then has the note twice.
Connect does not answer on this computer
Message on screen
Connect does not answer on this computer
Restart the computer. If that does not help, ask your IT to check in Windows Services that the MediSyncConnectHub service is running.
Messages for each PVS
Each of these messages appears with one PVS only. The article for that PVS explains the steps.
T2med
| Message | What to do |
|---|---|
| No click on DP seen yet. Open a patient in T2med and click DP. | Switch on access and add the DP button. See Connect to T2med. Then click Check. |
| A note waits for … | Open the patient in T2med and click DP, then MediSync. Do this within 24 hours. More |
DURIA
| Message | What to do |
|---|---|
| No text group for diagnoses is open to MediSync. Notes arrive, diagnoses do not. | Ask DURIA support to give MediSync access to the text group. See Preparation in DURIA. Then click Check. |
Medical Office
| Message | What to do |
|---|---|
| No file from … in the export folder yet. Start MediSync once for a patient in …. | Check the Auftrag (order). See Create the Auftrag MSYN01. Then click Check. |
Quincy
| Message | What to do |
|---|---|
| No file from … in the export folder yet. Start MediSync once for a patient in …. | Check the GDT link and the MediSync button. See Set up Quincy. Then click Check. |
Contact support
Send MediSync support the message, the time of the entry and the name of your PVS. Do not include patient names. Your IT can also copy technical diagnostics. In Connect, switch on Settings›Advanced view for IT, then click Advanced›Copy diagnostics. The diagnostics contain no patient data. To reach support, see Contact support.